6000W pure sine wave inverter 

Product Features :

High transform efficiency 、fast start;

Pure sine wave output waveform;

Softstart function;

Strong adaptability and stability ;

With automatic over-current and output short circuit protection to avoid damage the equipment;

Temperature controlled fan,safe&efficient;

Safe and reliable with built in fuse.

1 year warranty (Remarks: Customizable input voltage such as 36V,72V,96V,110V etc; output voltage such as 120v, 130v, 200V,240v, etc;Many kinds of socket are available).

Performance Characteristics:

Model

P6000-12-110

P6000-24-110

P6000-48-110

P6000-12-220

P6000-24-220

P6000-48-220

Power

6000W

6000W

6000W

6000W

6000W

6000W

Peak Power

12000W(within 5 millisecond)

DC Input Voltage

12V

24V

48V

12V

24V

48V

AC Output Voltage

110VAC±10%

220VAC±5%

No-load Current

<2.7A(DC13V)

<1.7A(DC26V)

<1.5A(DC52)

<2.7A(DC13V)

<1.7A(DC26V)

<1.5A(DC52)

AC Output Frequency

50HZ±1%/60HZ±1%

Output waveform

pure sine wave

Wave Distortion

THD<3%

Full Load Efficiency

>86%(DC13V)

>88%(DC26V)

>90%(DC52V)

>86%(DC13V)

>88%(DC26V)

>90%(DC52V)

DC Input Voltage Range

11V~15.5V

22V~31V

44V~62V

11V~15.5V

22V~31V

44V~62V

Lower Voltage Alarm

11±0.3V

22±0.5V

44±1V

11±0.3V

22±0.5V

44±1V

Lower Voltage Shutoff

10.5±0.3V

21±0.3V

42±0.5V

10.5±0.3V

21±0.3V

42±0.5V

Higher Voltage Shutoff

15.5±0.3V

31±0.5V

62±0.5V

15.5±0.3V

31±0.5V

62±0.5V

Lower Voltage Recovery

12.4±0.1V

24.8±0.2V

49.6±0.3V

12.4±0.1V

24.8±0.2V

49.6±0.3V

Higher Voltage Recovery

15.4±0.1V

30.8±0.2V

61.8±0.5V

15.4±0.2V

30.8±0.4V

61.8±0.5V

Over-load Shutoff

111%~113%

Protect Function

           Lower voltage:  Green LED light on; the buzzer alarms; the inverter recovers to be normal automatically

Higher Voltage:  Red LED light on;the inverter recovers to be normal automatically

Over-load: Red LED light on;the inverter recovers to be normal automatically

           Over-Temperature: Red LED light on; the buzzer alarms; the inverter recovers to be normal automatically

                             Short-Circuit(within 2 seconds):the inverter recovers to be normal automatically

                             The anode and the cathode are connected in the wrong way: the fuse blowouts

Operating Temperature

–10℃- +50℃

Storage Temperature

–30- +70℃

Humidity

20%~90%RH without condensation

Operating Altitude

≦1200m

Net Size

545*199*146mm

 Net Weight

14±0.05kg

13.46±0.07kg

13.2±0.07kg

14±0.05kg

13.46±0.07kg

13.46±0.05kg

Packaging Size

665*285*240mm(1pc)

Gross Weight

17.2±0.1kg

15.9±0.1kg

15±0.1kg

17.2±0.2KG

15.9±0.1kg

14.9±0.1kg